A temperature influenced bimetal disc with double contacts will open/close a circuit when the required response temperature is reached.

The current goes through the bimetal disc, therefore a combination of current and temperature sensitivity is possible. Heat is transmitted from all sides via convection, radiation in gaseous or solid media. The rhomboid surface conducts heat directly onto the bimetal snap disc, therefore the device is also suitable as surface temperature detector.


Technical Data
Temperature Range 80 … 160 C in 10° steps
Wire
Shrinking cap or sleeve
   
       
   
   
 

 
Tolerance ±5K marked as "B", other on request
Switching principal Temperature and current dependent
Function Normally closed automatically reset
Rated Voltage 0 … 250v ac
Rated Current 0 … 2, 5 Amp PF1
  0 … 1, 6 Amp PF 0,6
Standard Wire 80mm, AWG 24, stranded; other on request
UL approved protector only with UL recognised wire
Number of cycles 10,000
Approvals

VDE pending according to EN 60 730
AZ: 20236-4510-7001
UL pending according to UL 547
File: E 173 279

Temperatures Available 80, 90, 100, 110, 120, 130 140, 150, 160° C

 
  
   

Tel : +44 (0) 151 647 3322
Fax : +44 (0) 151 647 3377